Este contrato foi adjudicado por 🇲🇹 Central Procurement and Supplies Unit por um montante de EUR 158,644 a 1 fornecedor. Foi publicado em 2013-10-30 através de open
A transparência neste processo reflete-se na publicação detalhada de todos os aspetos do contrato e dos seus resultados.
Entidade compradora🇲🇹 Central Procurement and Supplies Unit Unidade compradoranão reportado Data de publicação2013-10-30 Estado do concursonão reportado DescriçãoTECHNICAL SPECIFICATIONS Totally implantable device to detect and treat ventricular tachycardia (VT) and ventricular fibrillation (VF) automatically.The device must:1 Detect VT and VF2 Discriminate VT/VF from supra-ventricular tachycardias using a variety of techniques3 Deliver appropriate therapy: antitachycardia pacing, low energy cardioversion, high energy defibrillation4 Deliver bradycardia back-up pacingThe device must be fully programmable non-invasively in all its essential parameters. The lead connectors should be compatible with international standards: IS-1 and DF-1 leads. The device must be implantable in a subcutaneous pre-pectoral pocket.Preference will be given to devices that are:1. Small and light.2. Equipped with more extensive criteria and proven algorithms to discriminate supra-ventricular from ventricular tachyarrhythmias.3. Equipped with user-friendly programmers.4. Capable of storing electrograms and a full range of diagnostics.5. Capable of minimising ventricular pacing in the presence of a satisfactory intrinsic rhythm.Longevity, diagnostics and extra features will be taken into consideration when awarding the tender.Quote must include:1. Cardioverter-defibrillator box.2. A variety of defibrillator / pacing electrodes and all accessories.3. External programmers (if not already available to the Health Department)4. Full product specialist support, including the presence of a specialist during the actual implantation procedure.Three separate prices must be given:A. ICD with ventricular pacing/sensing onlyB. ICD with atrial and ventricular pacing/sensingC. ICD with atrial and multi-site ventricular pacing/sensingThe tenderer is to supply the following information about each of the products offered and compile it as per the following chart:1. Volume of device cm32. Weight of device g3. Dimensions of device (length x breadth x thickness) mm4. Maximum delivered energy J5. Charge time to maximum delivered energy(at beginning of life with formed capacitors) s.6. Total EGM storage capacity min7. Longevity at 100 % pacing (2.5 V, 0.4 ms, 60 bpm, 500 W); 12 months shelf-life; quarterly shocks y8. Longevity reduction due to EGM pre-storage on for the life of the device y9. Presence of atrial fibrillation pacing suppression algorithm yes/no10. Presence of algorithm to reduce unnecessary ventricular pacing yes/noRegarding the SVT differentiation algorithm in dual-chamber or CRT devices, the tenderer is to supply the following additional information as per the following chart:Name of differentiation algorithm:Sensitivity: %.Specificity: %.Positive predictive value: %.Data in above two tables is to be backed by scientific studies which must be provided.The tenderer should also supply dummy devices of identical physical size and weight (unless similar units have already been implanted previously).The Health Department reserves the right to choose to purchase the device that best fits our specifications, taking into consideration the particular clinical needs of the individual patient into which the implant will be performed.The validity of the offer should be for 12 months. Purchase will be made whenever the clinical need arises. Delivery time should be no longer than 72 hours from confirmation of order.If better products have been developed from the time the tender is adjudicated to the time the device is actually needed, the Health Department reserves the right to purchase the better product.Preference will be given to pacing systems that are MRI-conditional.GPS 14147T12CCS.Adjudicações
Esta adjudicação foi concedida a V.J. Salomone Pharma Ltd por Central Procurement and Supplies Unit por um montante de EUR 158,644. O processo de contratação foi conduzido através de open para a categoria de goods. A adjudicação foi concedida em 2013-10-02. Esta é a adjudicação número 3.
Este contrato tem múltiplas adjudicações. Esta é a adjudicação número 3. Ver outras adjudicações para este contrato
| Fornecedor | Montante | Data de adjudicação | Número de adjudicação |
|---|---|---|---|
| 🇲🇹 V.J. Salomone Pharma Ltd | EUR 158,644 | 2013-10-02 | 3 |
Contexto de mercado e oportunidades
A execução deste contrato permite que a entidade Central Procurement and Supplies Unit cumpra os seus objetivos de serviço público de forma eficiente.
A modalidade de compra open garante que o processo é transparente e conforme às regulamentações.
A transparência neste processo reflete-se na publicação detalhada de todos os aspetos do contrato e dos seus resultados.
Esta transparência na contratação pública promove a concorrência justa, previne a corrupção e garante que os recursos públicos são utilizados de forma eficiente para o benefício dos cidadãos.
Dados adicionais
Número do ContratoMT_ocds-70d2nz-331ab244-44ee-4f67-8544-2e3287259868-award-3Data de publicação2013-10-30Data do contratonão reportadoData de adjudicação2013-10-02CategoriasgoodsModalidade de compraopenDetalhes do métodopt_openEstadonão reportadoFontes de dados
Sociedad.info publica dados de fontes oficiais, em cumprimento das leis de acesso à informação pública. O acesso público a esses dados é um direito cidadão que ajuda no controle do governo. Esses dados, incluindo nomes e identificadores, já são públicos na fonte oficial. Leia nossa política de privacidade.